| Viking | Metric | TDK | Murata | Sumida | T-Yuden | Tokin | Cal-Chip | Vishay-Dale | Ceratech | Samsung | Steward | Fair-Rite | ACT | Abracom | AOBA |
| CB02(0402) | 100505 | MMZ1005S | BLM15A | x | BK1005 | N1005ZA | x | ILBB0402 | HB-1□1005 | CIB/CIM | LI0402 | x | x | ACML0204 | FBM0204S |
| CB03(0603) | 160808 | MMZ1608S | BLM18A | x | BK1608 | N1608ZAN1608ZE | FB160808 | ILBB0603 | HB-1□1608 | CIB/CIM | LI0603 | 250603~Y0 | △CB0603 | ACML0603 | FBM0603S |
| CB05(0805) | 201209 | MMZ2012S | BLM21A | x | BK2126 | N2012ZAN2012ZE | FB201209 | ILBB0805 | HB-1□2012 | CIB/CIM | LI0805 | 250805~Y0 | △CB0805 | ACML0805 | FBM0805S |
| CB04(1204) | 321611 | x | BLM31A | x | x | N3216Z | FB321616 | x | HB-1□3216 | CIB/CIM | LI1206 | 251206~Y0 | △CB1206 | ACML1206 | FBM1206S |
| CB06(1206) | 321616 | x | x | x | x | N3216Z | FB321616 | x | HB-1□3216 | CIB/CIM | x | 251206~Y0 | △CB1201 | ACML1206 | FBM1206S |
| CB10(1210) | 322513 | x | x | x | x | x | FB322513 | ILBB1210 | x | CIB/CIM | LI1806 | x | △CB1806 | x | FBM1210S |
| CB08(1808) | 451616 | x | BLM41A | x | x | x | FB451616 | ILBB1812 | HB-1□4516 | CIB/CIM | x | 121806~Y0 | △CB1806 | x | FBM1806S |
| CB12(1812) | 453215 | x | x | x | x | x | FB453215 | ILBB1816 | HB-1□4532 | CIB/CIM | x | x | △CB1812 | x | FBM1812S |
CB series (High Current-"H")
| Viking | Metric | TDK | Murata | Sumida | T-Yuden | Tokin | Cal-Chip | Vishay-Dale | Ceratech | Samsung | Steward | Fair-Rite | ACT | Abracom | AOBA |
| CB02(0402) | 100505 | x | x | x | x | x | x | x | x | x | x | x | x | x | x |
| CB03(0603) | 160808 | MPZ1608S | BLM18P | x | FB1608 | x | x | ILHB0603 | x | CIC/CIS | HI/MI0603 | x | x | x | FBM0603P |
| CB05(0805) | 201209 | MPZ2012S | BLM21P | x | FB2125 | x | x | ILHB0805 | x | CIC/CIS | HI/MI0805 | x | △0805-□A | x | FMB0805P |
| CB04(1204) | 321611 | x | BLM31P | x | FB3216 | x | x | ILHB1206 | x | CIC/CIS | HI/MI1206 | x | △1206-□A | x | FMB1206P |
| CB10(1210) | 322513 | x | x | x | x | x | x | x | x | CIC/CIS | x | x | △1201-□A | x | FBM1210P |
| CB08(1808) | 451616 | x | BLM41P | x | FB4516 | x | x | ILHB1806 | x | CIC/CIS | HI/MI1806 | 251806~Y6 | △1806-□A | x | FBM1806P |
| CB12(1812) | 453215 | x | x | x | x | x | x | ILHB1812 | x | CIC/CIS | HI/MI1812 | 251812~Y6 | △1812-□A | x | FBM1812P |
CB series (For High Speed Singals use) Code "Q"=ui 75
| Viking | Metric | TDK | Murata | Sumida | T-Yuden | Tokin | Cal-Chip | Vishay-Dale | Ceratech | Samsung | Steward | Fair-Rite | ACT | Abracom | AOBA |
| CB02(0402) | 100505 | x | BLM15B | x | x | x | x | x | x | x | x | x | x | x | x |
| CB03(0603) | 160808 | MMZ1608Y | BLM18B | x | x | x | x | x | x | x | x | 250603~Z0 | x | x | FBM0603N |
| CB05(0805) | 201209 | MMZ2012Y | BLM21B | x | x | x | x | x | x | x | x | 250805~Z0 | x | x | FBM0805N |
| CB04(1204) | 321611 | x | BLM31B | x | x | x | x | ILB1206 | x | x | x | x | x | x | FBM1206N |